If you're interested in becoming a contributor or requesting changes then click here to join the discord

Difference between revisions of "Category:Companies"

From Brain Computer Interface Wiki
Jump to navigation Jump to search
(Created page with "Organizations that develop BCI hardware or software for commercialization.")
 
Line 1: Line 1:
 
Organizations that develop BCI hardware or software for commercialization.
 
Organizations that develop BCI hardware or software for commercialization.
 +
 +
 +
Here's what the columns in this table mean:
 +
 +
* Noninvasive Hardware - Indicates whether a company produces noninvasive mind reading hardware, like an eeg cap.
 +
* Invasive Hardware - Indicates whether a company produces invasive mind reading technology, like electrodes in the brain.
 +
* End-user Software - Indicates whether a company builds end-user applications that use bci hardware.
 +
* Development Platform - Indicates whether a company develops tools for building end-user applications that use bci hardware.
 +
* Country - Country of origin.
 +
* Year founded - year the company was founded.
 +
 +
{| class="wikitable sortable"
 +
!Name
 +
!Noninvasive Hardware
 +
!Invasive Hardware
 +
!End-user Software
 +
!Development Platform
 +
!Country
 +
!Year Founded
 +
![[Application Categories]]
 +
![[Brain Computer Interface Classification|BCI Categories]]
 +
!Neuroimaging Techniques
 +
!Neurostimulation Techniques
 +
|-
 +
|[[Neuralink]]
 +
|False
 +
|True
 +
|True
 +
|False
 +
|US
 +
|2016
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI
 +
|[[IEEG|ECoG/iEEG]]
 +
|[[EBS]]
 +
|-
 +
|[[OpenBCI]]
 +
|True
 +
|False
 +
|False
 +
|True
 +
|US
 +
|2013
 +
|Clinical, RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Kernel]]
 +
|True
 +
|False
 +
|False
 +
|False
 +
|US
 +
|2016
 +
|Clinical, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[fNIRS]]
 +
|
 +
|-
 +
|[[Openwater]]
 +
|True
 +
|False
 +
|False
 +
|False
 +
|US
 +
|2016
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI
 +
|[[fNIRS]], [[fUS]]
 +
|
 +
|-
 +
|[[Paradromics]]
 +
|False
 +
|True
 +
|False
 +
|False
 +
|US
 +
|2015
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI
 +
|[[IEEG|ECoG/iEEG]]
 +
|[[EBS]]
 +
|-
 +
|[[Synchron]]
 +
|False
 +
|True
 +
|True
 +
|False
 +
|US
 +
|2016
 +
|Clinical, RC/UI
 +
|[A] Open-Loop Efferent BCI
 +
|[[IEEG|ECoG/iEEG]]
 +
|
 +
|-
 +
|[[EMOTIV]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|2011
 +
|RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[NextMind]]
 +
|True
 +
|False
 +
|False
 +
|True
 +
|FR
 +
|2017
 +
|RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Blackrock Microsystems]]
 +
|False
 +
|True
 +
|False
 +
|True
 +
|US
 +
|2008
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[IEEG|ECoG/iEEG]]
 +
|[[EBS]]
 +
|-
 +
|[[Neurable]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|2015
 +
|RC/UI
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[BIOS Health]]
 +
|False
 +
|True
 +
|True
 +
|False
 +
|UK
 +
|2015
 +
|Clinical
 +
|[E] Bidirectional Afferent Closed-Loop BCI
 +
|[[Electrocardiography|ECG/EKG]]
 +
|[[Microstimulation]]
 +
|-
 +
|[[Flow Neuroscience]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|SE
 +
|2016
 +
|Clinical
 +
|[B] Open-Loop Afferent BCI
 +
|
 +
|[[tDCS]]
 +
|-
 +
|[[Bitbrain]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|ES
 +
|2010
 +
|Clinical, RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]], [[Electrocardiography|ECG/EKG]]
 +
|
 +
|-
 +
|[[Halo Neuroscience]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|2013
 +
|Motor-Sensory Augmentation
 +
|[B] Open-Loop Afferent BCI
 +
|
 +
|[[tDCS]]
 +
|-
 +
|[[MindMaze]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|CH
 +
|2012
 +
|Clinical, RC/UI
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]], [[Electrocardiography|ECG/EKG]]
 +
|
 +
|-
 +
|[[Neuroleap]]
 +
|True
 +
|False
 +
|False
 +
|False
 +
|IN
 +
|2017
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Neuro Dive]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|RU
 +
|2019
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Petal Technology]]
 +
|False
 +
|False
 +
|False
 +
|True
 +
|US
 +
|2017
 +
|Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[IDUN Technologies]]
 +
|True
 +
|False
 +
|False
 +
|False
 +
|CH
 +
|2017
 +
|Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Dreem]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|2014
 +
|Subjective Measurement
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Cortex Labs]]
 +
|False
 +
|False
 +
|True
 +
|False
 +
|AU
 +
|2010
 +
|RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[NeuroPace]]
 +
|False
 +
|True
 +
|True
 +
|False
 +
|US
 +
|1997
 +
|Clinical
 +
|[E] Bidirectional Afferent Closed-Loop BCI
 +
|[[EEG]]
 +
|[[DBS]]
 +
|-
 +
|[[G.tec medical engineering GmbH|G.tec]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|AT
 +
|1999
 +
|Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]], [[fNIRS]]
 +
|
 +
|-
 +
|[[Actipulse Neuroscience]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|2017
 +
|Clinical
 +
|[B] Open-Loop Afferent BCI
 +
|
 +
|[[TMS]]
 +
|-
 +
|[[Advanced Brain Monitoring]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|US
 +
|1997
 +
|Clinical, RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]], [[Electrocardiography|ECG]]
 +
|
 +
|-
 +
|[[Aleva Neurotherapeutics]]
 +
|False
 +
|True
 +
|True
 +
|False
 +
|CH
 +
|2008
 +
|Clinical
 +
|[B] Open-Loop Afferent BCI
 +
|
 +
|[[DBS]]
 +
|-
 +
|[[ANT Neuro]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|NL
 +
|1996
 +
|Clinical
 +
|[A] Open-Loop Efferent BCI, [B] Open-Loop Afferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]], [[Electromyography|EMG]], [[MRI]],[[MEG]]
 +
|[[TMS]]
 +
|-
 +
|[[Axorus]]
 +
|False
 +
|True
 +
|False
 +
|False
 +
|FR
 +
|2019
 +
|Clinical
 +
|[E] Bidirectional Afferent Closed-Loop BCI
 +
|[[EEG]]
 +
|[[Microstimulation]]
 +
|-
 +
|[[Backyard Brains]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|US
 +
|2009
 +
|RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]], [[Electrocardiography|ECG]], [[Electromyography|EMG]]
 +
|[[EMS]]
 +
|-
 +
|[[Bio-Signal Technologies]]
 +
|True
 +
|True
 +
|True
 +
|False
 +
|US
 +
|2016
 +
|Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|[A] Open-Loop Efferent BCI, [B] Open-Loop Afferent BCI, [C] Closed-Loop Efferent BCI, [E] Bidirectional Afferent Closed-Loop BCI
 +
|[[EEG]]
 +
|[[Microstimulation]], [[Optogenetics]]
 +
|-
 +
|[[BioSemi]]
 +
|True
 +
|False
 +
|True
 +
|False
 +
|NL
 +
|1998
 +
|Clinical, RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[Brain Products GmbH]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|DE
 +
|1997
 +
|Clinical, RC/UI, Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[BrainAlive]]
 +
|False
 +
|False
 +
|True
 +
|False
 +
|IN
 +
|2018
 +
|Subjective Measurement
 +
|[A] Open-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|-
 +
|[[BrainCo]]
 +
|True
 +
|False
 +
|True
 +
|True
 +
|US
 +
|2015
 +
|RC/UI, Subjective Measurement, Motor-Sensory Augmentation
 +
|[A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI
 +
|[[EEG]]
 +
|
 +
|}

Revision as of 20:00, 1 May 2021

Organizations that develop BCI hardware or software for commercialization.


Here's what the columns in this table mean:

  • Noninvasive Hardware - Indicates whether a company produces noninvasive mind reading hardware, like an eeg cap.
  • Invasive Hardware - Indicates whether a company produces invasive mind reading technology, like electrodes in the brain.
  • End-user Software - Indicates whether a company builds end-user applications that use bci hardware.
  • Development Platform - Indicates whether a company develops tools for building end-user applications that use bci hardware.
  • Country - Country of origin.
  • Year founded - year the company was founded.
Name Noninvasive Hardware Invasive Hardware End-user Software Development Platform Country Year Founded Application Categories BCI Categories Neuroimaging Techniques Neurostimulation Techniques
Neuralink False True True False US 2016 Clinical [A] Open-Loop Efferent BCI ECoG/iEEG EBS
OpenBCI True False False True US 2013 Clinical, RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG
Kernel True False False False US 2016 Clinical, Subjective Measurement [A] Open-Loop Efferent BCI fNIRS
Openwater True False False False US 2016 Clinical [A] Open-Loop Efferent BCI fNIRS, fUS
Paradromics False True False False US 2015 Clinical [A] Open-Loop Efferent BCI ECoG/iEEG EBS
Synchron False True True False US 2016 Clinical, RC/UI [A] Open-Loop Efferent BCI ECoG/iEEG
EMOTIV True False True False US 2011 RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG
NextMind True False False True FR 2017 RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG
Blackrock Microsystems False True False True US 2008 Clinical [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI ECoG/iEEG EBS
Neurable True False True False US 2015 RC/UI [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG
BIOS Health False True True False UK 2015 Clinical [E] Bidirectional Afferent Closed-Loop BCI ECG/EKG Microstimulation
Flow Neuroscience True False True False SE 2016 Clinical [B] Open-Loop Afferent BCI tDCS
Bitbrain True False True True ES 2010 Clinical, RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG, ECG/EKG
Halo Neuroscience True False True False US 2013 Motor-Sensory Augmentation [B] Open-Loop Afferent BCI tDCS
MindMaze True False True False CH 2012 Clinical, RC/UI [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG, ECG/EKG
Neuroleap True False False False IN 2017 Clinical [A] Open-Loop Efferent BCI EEG
Neuro Dive True False True True RU 2019 Clinical [A] Open-Loop Efferent BCI EEG
Petal Technology False False False True US 2017 Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation EEG
IDUN Technologies True False False False CH 2017 Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation [A] Open-Loop Efferent BCI EEG
Dreem True False True False US 2014 Subjective Measurement [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG
Cortex Labs False False True False AU 2010 RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG
NeuroPace False True True False US 1997 Clinical [E] Bidirectional Afferent Closed-Loop BCI EEG DBS
G.tec True False True True AT 1999 Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG, fNIRS
Actipulse Neuroscience True False True False US 2017 Clinical [B] Open-Loop Afferent BCI TMS
Advanced Brain Monitoring True False True False US 1997 Clinical, RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG, ECG
Aleva Neurotherapeutics False True True False CH 2008 Clinical [B] Open-Loop Afferent BCI DBS
ANT Neuro True False True False NL 1996 Clinical [A] Open-Loop Efferent BCI, [B] Open-Loop Afferent BCI, [C] Closed-Loop Efferent BCI EEG, EMG, MRI,MEG TMS
Axorus False True False False FR 2019 Clinical [E] Bidirectional Afferent Closed-Loop BCI EEG Microstimulation
Backyard Brains True False True True US 2009 RC/UI, Subjective Measurement, Motor-Sensory Augmentation [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG, ECG, EMG EMS
Bio-Signal Technologies True True True False US 2016 Clinical, RC/UI, Subjective Measurement, Motor-Sensory Augmentation [A] Open-Loop Efferent BCI, [B] Open-Loop Afferent BCI, [C] Closed-Loop Efferent BCI, [E] Bidirectional Afferent Closed-Loop BCI EEG Microstimulation, Optogenetics
BioSemi True False True False NL 1998 Clinical, RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG
Brain Products GmbH True False True True DE 1997 Clinical, RC/UI, Subjective Measurement [A] Open-Loop Efferent BCI EEG
BrainAlive False False True False IN 2018 Subjective Measurement [A] Open-Loop Efferent BCI EEG
BrainCo True False True True US 2015 RC/UI, Subjective Measurement, Motor-Sensory Augmentation [A] Open-Loop Efferent BCI, [C] Closed-Loop Efferent BCI EEG

Pages in category "Companies"

The following 200 pages are in this category, out of 677 total.

(previous page) (next page)
(previous page) (next page)